The right pipe diameter keeps flow velocity within the recommended range. Too high causes pressure loss and heating; too low means unnecessary cost.
⚙ Open the Hydraulic Calculator →Q: L/min, A: m², v: m/s
A = Q / (v × 60000) [m²], D: mm
| Quantity | Symbol | Unit |
|---|---|---|
| Flow | Q | L/min |
| Velocity | v | m/s |
| Area | A | m² (×10⁶ → mm²) |
| Inner diameter | D | mm |
Given: Flow Q = 40 L/min, target velocity v = 4 m/s (pressure line).
1) Area: A = 40 / (4 × 60000) = 1.667×10⁻⁴ m² = 166.7 mm²
2) Inner diameter: D = √(4 × 166.7 / π) = 14.6 mm → nearest larger standard ≥ 16 mm
Suction line 0.5–1.5 m/s, pressure line 3–6 m/s, return line 2–4 m/s.
Pressure loss, turbulence, heating and noise increase. That is why the diameter is usually rounded up to the next standard.
The computed diameter is an in-between value; choosing the nearest larger standard keeps velocity on the safe (slightly lower) side.